Ghost² Knowledge Base

The one that started it all... The Dr. Dabber Ghost²™ is a reimagining of the device that launched Dr. Dabber® back in 2013. Refined, re-engineered, and reborn for the modern era. The Ghost² embodies over a decade of innovation, feedback, and obsession with the perfect portable dab.


The Basics

Ghost² Unboxing

Radial sidewall heating

Clean vapor pathway

5 precision temperature settings

Dynamic heating modes

Pass through charging

15 minute auto shutoff time

1,000 mAh LiPo battery cell

Over-voltage, over-current, under-voltage, over-temperature, short-circuit, and reverse-polarity protection built into the unit, charger, and battery


How to Use Your Ghost²

Ghost² User Guide
Load your concentrates directly on the bottom of the e-Chamber for best results. Please be aware of how much product you are loading in the e-Chamber. We recommend using about 1/2 a pea size amount at a time. Overloading will restrict airflow and in turn, produce less vapor.

1. Hold button for 2 seconds to turn the unit on/off.

2. Click button once to show current temp setting. Click button again within 3 seconds to change temp setting.

3. Click button 3 times to change dynamic heating mode.

4. Flip top open to reveal heating chamber.

5. Load concentrates directly on the bottom of heating chamber and close top.

6. Click button 2 times to start a heating cycle. Unit will pulse red while heating. Unit will illuminate green and vibrate when Ghost² is ready to use. Take long, slow drags for best results.

Enjoy vapor!

Heating cycle may be canceled at any time with 1 click of the button during heating.

The vapor travels directly from the e-Chamber to the mouthpiece via a glazed alumina ceramic vapor pathway (airflow regulator). The airflow regulator and mouthpiece are easy to clean and will not degrade flavor or absorb oils.

Do not dry burn e-Chambers. This will help extend the life and flavor of these parts. There should always be a small amount of oil in the e-Chamber while in use. Your e-Chambers will begin to season overtime, allowing them to produce more vapor with less concentrates. e-Chambers are not covered under warranty as they are disposable components and will need to be replaced over time. We recommend between 3-12 months depending on usage and cleaning habits.  
Changing your e-Chamber is simply another part of successful vaporizer care. Here are some signs that your e-Chamber may need to be changed:
-It is visually dark, crusted or damaged.
-The dish is cracked or broken.
-You are experiencing a “burnt” taste, even after thoroughly cleaning your device.
-Your e-Chamber is having leakage issues.

-You are experiencing decreased vapor production.

When installing a new e-Chamber, the Ghost² unit must be recalibrated with the new e-Chamber before first use. This is accomplished in the following procedures:
1. Unit must be turned OFF and unplugged for 15 minutes prior to the next step in recalibration. Ensure the main unit and e-Chamber are at room temperature.
2. While the unit is OFF, click the button 4 times with the user holding down the button on the 4th press until lights blink. Lights will blink GREEN (x3) to indicate successful recalibration. Lights will blink RED (x3) to indicate an unsuccessful recalibration.
Unsuccessful recalibration may be the result of a difference in temperature between the e-Chamber and the main unit, unclean electrode connections, or an e-Chamber not properly installed in the unit. Several recalibration attempts may be necessary before a successful recalibration.

Ghost² Temperatures & Dynamic Heating Modes

Click button once to show current temp setting. Click button again within 3 seconds to change temp setting. The light will pulse the new temp setting color. Temperature settings breakdown (in approximation):

Purple: 420 Blue: 450 Cyan: 480 Yellow: 510 White: 540

Lower temperature settings are recommended for maximizing flavor. Higher temperatures are recommended for maximizing vapor production.

Dynamic Heating modes

Click button 3 times to change heating mode. The light will illuminate in a pattern representing the heating mode.

Downward = Descent

Pulse = Steady

Upward = Ascent

Descent: The temperature will slowly decrease once it reaches the set temperature by the user. This heating mode simulates the thermal decay of a banger, naturally cooling as time passes. This is the default setting.

Ascent: The temperature will slowly increase once it reaches the set temperature by the user. This heating mode simulates torching the banger as you inhale, increasing temperature consistently during the hold time.

Steady: The unit will adjust the temperature to hold steady throughout the entire heating cycle. This heating mode is how most eRigs & vape pens function.

Ghost² will remember the last temp setting and heating mode when the unit is turned on/off. No need to reset the temp and mode each time.


Charging your Ghost²

We recommend charging the device fully before initial use. We only recommend using the official charging cable that is included with your Ghost² unit. 

The Ghost² has a 15 minute auto shutoff to help increase battery life while not in use. This also protects against accidental button presses when unit is stored in a bag or pocket.

The light will blink WHITE 3 times when the battery needs to be recharged. The Ghost² uses a fast charge USB-C charging cable. Charging your Ghost² is easy, just plug your charging cable into any USB-C port (or AC Adapter for faster charging) and insert the other end of the cable into the charging port on the bottom of the unit. Do not use too much force when plugging your charging cable into the unit. The light on the unit will pulse upwards when charging. When the device is fully charged, the light on the unit will stay steady white. The battery lasts for approximately 20 heating cycles and takes about 1 hour to fully charge. This unit also offers pass through charging, which means you may use the unit while it charges. 

You may check the battery status by clicking the button 4 times while the unit is powered on. The unit will light up to indicate the battery percentage:

Green: 70% or higher

Yellow: 30% - 70%

Red: 30% or lower


Cleaning your Ghost²

Cleaning Guide

We recommend using isopropyl alcohol (ISO) to clean any residue in and around the e-Chamber and heating chamber. We only recommend using a paper towel dipped in warm water to clean the shell of the unit. ISO may cause the finish on the shell to fade.
1. Pull the mouthpiece and silicone top off the unit and remove the built in airflow regulator.
2. Pour ISO into a small glass.
3. Drop your mouthpiece, silicone top, and airflow regulator into the ISO, ensuring they are completely submerged. Leave in ISO for no more than 20 minutes. 
4. Heat the e-Chamber up slightly, about 3-5 seconds, and use a dry cotton swab to soak up any residue inside the e-Chamber. Then use a cotton swab dipped in ISO to remove any stubborn residue on the bottom and side walls of the e-Chamber. Do not use too much force when cleaning the inside of the e-Chamber. Dry heat the e-Chamber for another 3-5 seconds to evaporate any left over ISO.
5. Let all items air dry completely for 20+ minutes.  
6.  Reassemble airflow regulator, silicone top, and mouthpiece and attach to unit.

*Do not leave airflow regulator and mouthpiece in ISO over the recommended time frame. This may damage the finish on these parts.*

*Do not soak e-Chambers in ISO or any other liquid and make sure they are completely dry of alcohol before use.*


Compatible Items

All Ghost² kits include a ceramic e-Chamber, glazed ceramic mouthpiece, silicone top, dab tool, and charging cable. We also offer additional accessories to be purchased separately. 


Troubleshooting

Make sure your battery is powered ON by holding the button for 2 seconds.

Make sure your battery is fully charged for best results.

Make sure all connection points between the e-Chamber and unit are clean. Use a cotton swab dipped in ISO to clean connection points.

The Ghost² will blink YELLOW 3 times to indicate a faulty connection with the e-Chamber or if the e-Chamber has ceased to function. Replace e-Chamber and test functionality.
Make sure your e-Chamber is fully threaded down on the battery. Finger tight is recommended. A loose connection to the battery may cause heating issues.

Fault Indicators

Overheating: LED will blink RED 3 times when attempting to heat to indicate the device is too hot.

Open Circuit: LED will Flash YELLOW 3 times when attempting to heat to indicate that the e-Chamber is missing or malfunctioning.

Short Circuit Fault: LED will Flash PINK 3 times when attempting to heat to indicate a fatal fault.

- PCB Fault

- Short Circuit

- Charging Fault

Unit Reset

Unit reset will set the device back to default settings. Only reset if unit is in a fault state.

While OFF: Click button 8 times and hold on the 8th click until LED flashes.

Success = LED will flash Red, Green, Blue

e-Chamber Recalibration

If you are experiencing temperature irregularities or installing a new e-Chamber, the Ghost² unit must be recalibrated in the following procedures:

1. Unit must be turned OFF and unplugged for 15 minutes prior to the next step in recalibration. Ensure the main unit and e-Chamber are at room temperature.
2. While the unit is OFF, click the button 4 times with the user holding down the button on the 4th press until lights blink. Lights will blink GREEN (x3) to indicate successful recalibration. Lights will blink RED (x3) to indicate an unsuccessful recalibration.


Find Us!

Feel free to check out our instruction videos by visiting our Dr. Dabber YouTube Channel or follow us on InstagramTwitterDiscord, and Facebook

Did this answer your question? Thanks for the feedback There was a problem submitting your feedback. Please try again later.

Still need help? Contact Us Contact Us